EYECRYL PHAKIC

Phakic Aspheric Hydrophilic Acrylic Foldable Intraocular Lens

EYECRYL PHAKIC Intraocular Lens (IOLs) are monofocal hydrophilic acrylic foldable single-piece posterior chamber intraocular lens. These IOLs are designed to be surgically implanted into the posterior chamber of the eye in ciliary sulcus in front of natural crystalline lens for correction or reduction of myopia.

eIFU
Publication
Contact

FEATURES

High Patient Satisfaction Ratio: With a patient satisfaction ratio of 94.7%, EYECRYL PHAKIC IOLs consistently meet or exceed the expectations of patients. This high satisfaction rate reflects positively on the effectiveness and reliability of the product.
Design: EYECRYL PHAKIC IOLs feature a foldable single-piece posterior chamber design, which facilitates ease of insertion through small incisions during surgery. The single-piece design minimizes the risk of intraocular lens dislocation and simplifies the surgical procedure for the ophthalmic surgeon. The aspheric optic design of the lenses contributes to better optical performance. By reducing spherical aberrations, this design enhances visual quality, particularly in low-light conditions, and may improve contrast sensitivity.
Biocompatible Material: The lenses are constructed from monofocal hydrophilic acrylic material, chosen for its biocompatibility and optical clarity.
Innovative Design Features: The inclusion of a central hole of 360 microns allows for the natural passage of Aqueous Humor, maintaining intraocular pressure and reducing the risk of complications such as glaucoma. Orientation marks aid in the proper implantation of the lens, ensuring optimal visual outcomes for the patient.

64% of the eyes gain one or more lines in CDVA
94.7% patient satisfaction ratio
Predictable, safe & effective outcomes
For correction or reduction of myopia
Significant improvement in visual acuity
Aspheric optic

SURGICAL APPLICATIONS

EYECRYL PHAKIC IOLs are primarily used in phakic adults who seek refractive correction without undergoing corneal refractive procedures such as LASIK or PRK. These lenses are implanted into the posterior chamber of the eye, positioned in front of the natural crystalline lens. They offer a viable alternative for individuals with thin corneas, dry eyes, or other contraindications to corneal refractive surgery.

ADVANTAGES

Visual Improvement: The significant improvement in visual acuity, coupled with high patient satisfaction, underscores the effectiveness of EYECRYL PHAKIC IOLs in achieving desirable visual outcomes.
Precision and Reliability: The precise calculator and orientation marks ensure accurate implantation of the lenses, minimizing the risk of postoperative complications and ensuring reliable outcomes for patients. The innovative design features of the lenses, such as the optimized hole size and smooth edges, increase patient comfort during and after surgery by reducing glare and halos, common complaints after refractive surgery.
Biocompatibility and Reversibility: The biocompatible nature of hydrophilic acrylic material reduces the risk of adverse reactions and complications. Additionally, the reversible nature of the procedure allows for the removal of the lens if necessary, preserving the structural integrity of the eye.
Tailored Solutions for Myopia: EYECRYL PHAKIC IOLs offer a tailored solution for myopia correction, addressing a common refractive error that affects a significant portion of the population.
Reversible Procedure: The reversible nature of the procedure allows for the easy removal of the lenses if necessary, preserving the structural integrity of the eye and providing patients with an added layer of safety and flexibility.

EYECRYL PHAKIC Intraocular Lens (IOLs) offers a comprehensive solution for refractive correction, providing patients with enhanced visual acuity, safety, and comfort. With its high success rate, versatility, and long-term stability, it remains a preferred choice for both surgeons and patients seeking effective refractive surgery options.

TECHNICAL SPECIFICATIONS

MATERIALHydrophilic Acrylic CQ UV
OPTIC TYPEAspheric
OPTIC SIZE6.50 mm
EFFECTIVE OPTIC SIZE4.65 mm to 5.50 mm
OVERALL SIZE11.0 mm to 14.0 mm
REFRACTIVE INDEX1.462
DIOPTER RANGE+10.0 D to -25.0 D (with 0.5D step)
IMPLANTATION SITEPosterior Chamber
STERILIZATIONSteam

AddItIonal Products

Additional products available for special orders in this segment

Models AvailableLens overall sizeDiopter range
PKC120NH6.5 x 12.0+10 D to -25.0 D
PKC125NH6.5 x 12.5+10 D to -25.0 D
PKC130NH6.5 x 13.0+10 D to -25.0 D
PKC130NH6.5 x 13.5+10 D to -25.0 D

Eyecryl Calculator

ser friendly & accurate Online Calculator provides Eyecryl Phakic model recommendation and Spherical Power to be implanted.
Visit: http://www.biotechcalculators.com/

SURGERY VIDEO

DOWNLOAD PRODUCT BROCHURE
ACCESS TO INNOVATION
Contact us
Categories
Company
Media
Follow Us

© Copyright Biotech /Terms Of Use - Privacy Policy

Version 2_CT_1212222